Dynamic Ratings Inc. - Dynamic Rating, Monitoring, Control and Communications for power transformers. www.dynamicratings.com
There are a wide variety of sensors and IED’s available to monitor the health of your power transformers. The data provided by many of these devices is complimentary and can be enhanced when combined with data from other sensors. Integrating the signals from each of these devices into a transformer management system is a critical step in turning data into information. Many asset managers have found the timely and accurate information provided by the TMS systems to be the missing link they required to more effectively manage their equipment and predict equipment failures and impending end of life issues.
Utilities are turning to on-line monitoring for a variety of reasons. Some are looking to improve the availability and reliability of their power transformers. Others are looking to reduce their operation and maintenance costs. The selection of the proper monitoring equipment is not the only factor that needs to be considered when pursuing on-line monitoring. To achieve your goals an implementation plan is also required to get the complete benefit of your investment.
Morgan Schaffer Systems www.morganschaffer.com
On-Line monitoring of dissolved hydrogen & dissolved water “CALISTO- keeping an eye on things”
On-line monitoring of a transformers status is critical, as detecting incipient faults will prevent equipment failure, costly repairs, unscheduled outages, and lost revenue. Morgan Schaffer Systems has addressed this issue by offering the industry its specialized, high-performance and cost effective hydrogen and moisture monitor, CALISTO.
Off-Line Equipment & Services “MYRKOS - Taking the lab to the field”
Transformers can be located in remote areas where access to a laboratory is restricted. Morgan Schaffer Systems now allows users to literally take the lab to the field by using their MYRKOS portable transformer fault gas analyzer. This allows users to rapidly analyze transformer oil to generate results of unparalleled precision and accuracy, right on-site. Not only does the unit measure the fault gases separately, it does so with repeatability better than or equal to ASTM D-3612 or IEC 567 standards, all within 100 seconds.
TransFluid Services, Inc. www.transfluidservices.com
TransFluid Services is uniquely qualified for all your transformer fluid handling needs whether commissioning a new transformer or restoring the oil quality to exceed new transformer fluid properties, we are at your service with nationwide capabilities